ATS For Genset
Product Details:
- IP Rating IP54
- Operating Temperature -10C to +55C
- Shape Rectangular
- Mounting Type Wall Mounted
- Efficiency Above 95%
- Humidity % Up to 95% RH
- Feature Automatic Start/Stop, Reliable Operation
- Click to View more
X
ATS For Genset Price And Quantity
- 1 Set
ATS For Genset Product Specifications
- Terminal Block
- Powder Coated
- PVC
- Grey
- 415 V AC
- 4 Pole
- 0.8
- 230-415 V AC
- 50 Hz
- Panel Mounted
- YES
- AC
- Above 95%
- Genset / Generator Panel
- Mild Steel
- 600mm x 400mm x 200mm
- Standard
- Low
- Automatic Start/Stop, Reliable Operation
- Three Phase
- Up to 95% RH
- Rectangular
- Wall Mounted
- IP54
- Automatic Transfer Switch (ATS)
- 35 kg
- -10C to +55C
- Overload, Short Circuit
ATS For Genset Trade Information
- Telegraphic Transfer (T/T)
- Yes
- Free samples are available
- Pallets with Wooden box
Product Description
Product Description
PM-NOx after treatment system is composed of DPF System, SCR and AOC. This converter also reduces NOx to meet the Euro 5 and 6.
- Simultaneously reduce PM 80% or more and NOx (NOx) 70% or more
- Applied to buses and construction equipments with large-sized diesel engines less than 16,000CC
Product Features
[Performance]
- Euro 3, Euro 4, Euro 5, Euro 6
THC reduction 98.0%
CO reduction 100%
NOx reduction 84.1%
PM reduction 94.0%
F.E. reduction 12.8%
Specification
[Size]
- Customization
Product Use
[Application]
- Diesel generator : 100kW - 5,000kW
- Small cogeneration system : 100kW - 10,000kW
- Boiler : 2ton - 10ton
Company Profile
Ceracomb Co., Ltd.
Ceracomb Co., Ltd. has been producing and supplying ceramic honeycombs using ceramics extrusion molding technology. We have been developing and supplying catalytic products for industrial hazardous gas eliminating, automobile exhaust gas purification, and filters for reducing soot. Moreover, the automobile particulate matter reduction device developed based on Ceracomb honeycomb and catalytic technology, is contributing greatly to the improvement of the fine dust / atmospheric environment which is becoming an issue in the 21st century.
Website : http://ceracomb.co.kr/english/
Advanced Control and Fast Switching
Equipped with a microprocessor-based controller, this ATS ensures swift transitions between mains and genset power in less than five seconds, safeguarding connected systems from interruptions. The manual override feature provides added control during maintenance or emergency situations, while clear indication lamps facilitate easy monitoring of operational status and faults.
Robust Design for Reliable Performance
Constructed with a powder-coated mild steel body and electrolytic copper busbars, the ATS guarantees durability and excellent conductivity. It supports a maximum current capacity of up to 250A, incorporates overload, short circuit, and overheating protection, and maintains high efficiency above 95%. The IP54 rating and standard panel mounting allow for versatile installation in varied environments.
Comprehensive Compliance and User Safety
Fully compliant with IS/IEC 60947-6-1 standards, this ATS enhances operational safety and reliability. The inclusion of potential-free contacts, PVC insulation material, terminal block connectors, and surface finish details ensures user protection as well as ease of integration into existing generator panels and systems.
FAQ's of ATS For Genset:
Q: How does the microprocessor-based controller enhance ATS operation?
A: The microprocessor-based controller intelligently manages the switching process, enabling rapid transition between mains and genset power in less than five seconds. This minimizes downtime and reduces electrical risks by automatically coordinating start and stop functions, ensuring reliable performance even during power fluctuations.Q: What safety protections are integrated into this ATS for genset?
A: The ATS panel features multiple levels of protection, including overload, short circuit, and overheating safeguards. It is compliant with IS/IEC 60947-6-1, designed to operate safely in humid environments up to 95% RH, and equipped with clear indication lamps for status and fault alerts, ensuring maximum safety during operation.Q: When should manual override be used on this ATS?
A: Manual override is recommended during maintenance, commissioning, or emergency situations when automatic switching is not desired. It allows operators or technicians to manually control the transfer between power sources, ensuring flexibility and safety when working on connected equipment.Q: Where is this ATS typically installed and how is it mounted?
A: This ATS is panel-mounted and designed for wall installation, making it suitable for generator panels in industrial, commercial, and institutional buildings. Its standard size and IP54 enclosure ensure it fits seamlessly into electrical distribution systems exposed to dust or moisture.Q: What is the process for connecting the ATS to a genset panel?
A: Connection is achieved through terminal block connectors, with the ATS mounted on the panel and wired into the generator and mains supply. Indication lamps, potential-free contacts, and protective measures are verified, followed by testing the automatic and manual operation for proper functioning.Q: How does using this ATS benefit generator panel operation?
A: This ATS enhances generator panel operation by enabling automatic and reliable transfer of power, ensuring seamless continuity. The fast switching time and comprehensive protection features safeguard critical equipment, reduce energy consumption, and maximize system uptime and efficiency.Tell us about your requirement
Price:
Quantity
Select Unit
- 50
- 100
- 200
- 250
- 500
- 1000+
Additional detail
Mobile number
Email

English
Spanish
French
German
Italian
Chinese (Simplified)
Japanese
Korean
Arabic
Portuguese